Valonix Fluid Systems — Specialty Gas Valves, Engineered for Puritysales@yuedukeji.cn  |  Get a quote
VX12 High Flow UHP Diaphragm Valve - 3/4 diaphragm valve Cv 2.8
VX12-LP · UHP Diaphragm Valves

VX12 High Flow UHP Diaphragm Valve

Three-quarter inch high flow valve with Cv 2.8, intended for distribution headers and VMB outlet sections.

Built for ultra high purity specialty gas service, the VX12-LP belongs to the UHP Diaphragm Valves family covering isolation, switching and flow control.

3/4 diaphragm valve Cv 2.8316L wetted bodyHelium leak tested

Request a Quote UHP Diaphragm Valves range

3/4Port size
300 PSIMax. pressure
2.8Cv
VCR face sealConnection

VX12 High Flow UHP Diaphragm Valve overview

The VX12-LP is a high purity specialty gas valve specified with 3/4 ports, a flow coefficient of 2.8 and a maximum working pressure of 300 PSI. Three-quarter inch high flow valve with Cv 2.8, intended for distribution headers and VMB outlet sections. It is intended for the point in a high purity gas system where a clean, repeatable shut-off or switching function is needed without introducing a packed stem seal into the process stream.

A multi-layer metal diaphragm is clamped between the body and the bonnet, forming a hermetic barrier between the process gas and the actuator. There is no sliding stem seal, no packing and no lubricant in the wetted path, which keeps particle generation and trapped volume extremely low. A short, smooth flow path and low internal volume make purge cycles fast, which matters when a line changes between reactive gases. Available end connections are vcr face seal (male/female), butt weld, so the same body can be used on face-sealed tool hook-ups, welded distribution headers or field-installed instrument lines.

Key features and design benefits

  • 3/4 ports, Cv 2.8 — sized for 3/4 diaphragm valve Cv 2.8 flow duty without excess dead volume
  • 300 PSI maximum working pressure with a reinforced seat and helium-tested pressure envelope
  • A multi-layer metal diaphragm is clamped between the body and the bonnet, forming a hermetic barrier between the process gas and the actuator.
  • Electropolished wetted surfaces for fast dry-down and low moisture retention
  • Manual or normally closed pneumatic actuation; pneumatic versions fail closed on loss of instrument air
  • VCR, butt weld, compression or cylinder-standard end connections to match the installation
  • Cleanroom assembly, double-bag packaging and per-valve leak records available

Technical specifications

Port size3/4
End connectionsVCR face seal (male/female), butt weld
Cv2.8
Max working pressureManual: 300 PSI, Pneumatic: 300 PSI
Actuator supply60-90 PSI
Model codeVX12-LP
Product familyUHP Diaphragm Valves
Body material316L VIM/VAR stainless steel, low inclusion
Sealing elementMulti-layer 316L metal diaphragm, nickel alloy option for halides
Wetted surface finishElectropolished, typical Ra 0.25 um (10 uin) or better
Leak testingHelium mass spectrometer, inboard and across seat; typical 1 x 10^-9 mbar l/s
Operating temperatureTypical -10 C to +80 C manual, -10 C to +65 C pneumatic
ActuationManual handwheel or normally closed pneumatic, 60-90 PSI instrument air
CleanlinessCleaned, dried and assembled for ultra high purity gas service
PackagingCleanroom double-bag, sealed for installation
DocumentationMaterial certificate, helium leak record, certificate of conformance

Values above describe the standard configuration of model VX12-LP. Final materials, seat, actuation, test limits and certification are confirmed on the order-specific datasheet issued with your quote.

Model comparison within the UHP Diaphragm Valves family

Select the body by flow demand rather than by port size alone. The table below compares the VX12-LP with its sibling models on the three parameters that drive a gas system design: port size, flow coefficient and maximum working pressure.

ModelPortCvMax. pressure
VX4-LP1/4, 3/80.27300 PSI
VX8-LP1/20.70300 PSI
VX16-LP1 in3.5300 PSI

Construction and wetted materials

A multi-layer metal diaphragm is clamped between the body and the bonnet, forming a hermetic barrier between the process gas and the actuator. There is no sliding stem seal, no packing and no lubricant in the wetted path, which keeps particle generation and trapped volume extremely low. For the VX12-LP, the wetted path is machined from 316L VIM/VAR stainless steel with low inclusion and controlled sulfur content, then electropolished. A nickel-based diaphragm or seat alloy can be substituted where halide or hydride gases demand it.

ComponentStandard specification
Body316L VIM/VAR stainless steel bar stock
Wetted finishElectropolished, typical Ra 0.25 um (10 uin) or better
Sealing elementMulti-layer 316L metal diaphragm, nickel alloy option for halides
ActuatorManual handwheel or normally closed pneumatic piston, 60-90 PSI supply
Process connectionVCR face seal (male/female), butt weld

End connections and port options

The VX12-LP is normally ordered with 3/4 ports. Connection choice affects both cleanliness and maintainability: VCR face seals give a repeatable metal-to-metal seal for tool hook-up, orbital butt welds suit permanent high purity headers, and compression fittings are used where a line must be assembled in the field.

ParameterAvailable option
Standard port3/4
End connectionsVCR face seal (male/female), butt weld
Seal standardVCR face seal / orbital butt weld / compression / CGA or DISS for cylinder service
ActuationManual, or normally closed pneumatic with 60-90 PSI instrument air
Optional documentationMaterial certificate, helium leak record, certificate of conformance

Gas compatibility and typical applications

Model VX12-LP is selected for silane (SiH4), ammonia (NH3), hydrogen chloride (HCl), chlorine (Cl2), nitrogen trifluoride (NF3), tungsten hexafluoride (WF6) and high purity N2, Ar, He and H2. Always state concentration, temperature and any moisture or oxygen limit so the wetted alloy and seat can be confirmed before release.

Installation, purging and handling

Install the VX12-LP with the flow direction and port orientation shown on the approved drawing. Keep the protective caps in place until the joint is made, tighten face-seal fittings to the specified torque, and purge with dry inert gas before introducing process gas. Because the internal volume is low, a short cyclic purge is normally enough to reach the required moisture level.

  • Handle with clean gloves in a controlled area; do not open the double bag until installation
  • Use orbital welding or certified face-seal glands on high purity headers
  • Purge with dry N2 or Ar and verify moisture / oxygen upstream before process gas
  • Helium leak check the assembled joint, then the inboard and across-seat envelope
  • Record the serial number, leak result and gas service in the system dossier

Ordering and configuration

Quote the model code and the options below. Where a gas is corrosive or pyrophoric, include the concentration so the diaphragm or seat alloy can be matched to the service.

Ordering parameterYour selection
Base modelVX12-LP — VX12 High Flow UHP Diaphragm Valve
Port size3/4
End connectionVCR face seal (male/female), butt weld
ActuationManual handwheel / normally closed pneumatic (60-90 PSI)
Wetted alloy316L VIM/VAR standard, nickel-based alloy by gas compatibility
DocumentationMaterial certificate, helium leak record, CoC (state if required)
Need a datasheet? Send the model code VX12-LP with your gas list, pressure, Cv target and connection through the quote form and we will return the confirmed configuration and lead time.

Ready to specify the VX12-LP?

Send the gas, pressure, flow and connection details — we will confirm the model, materials and lead time.

Request a Quote

Related models and alternatives

Other valves in the UHP Diaphragm Valves family and adjacent groups that may suit a different Cv, pressure or port requirement.

Frequently Asked Questions

What are the key specifications of the VX12-LP?

The VX12-LP is supplied with 3/4 ports, a maximum working pressure of 300 PSI and a Cv of 2.8. End connections are vcr face seal (male/female), butt weld. The full specification table on this page lists materials, leak testing, actuation and cleanliness requirements.

Is the VX12-LP suitable for corrosive or toxic specialty gases?

It is used with silane (SiH4), ammonia (NH3), hydrogen chloride (HCl), chlorine (Cl2), nitrogen trifluoride (NF3), tungsten hexafluoride (WF6) and high purity N2, Ar, He and H2. Compatibility depends on the wetted alloy and the sealing element, so state the gas and concentration when requesting a quote and we will confirm the material selection.

How is the VX12-LP actuated and what is its safe state?

Standard configurations are a manual handwheel or a normally closed pneumatic actuator with 60-90 PSI instrument air. Pneumatic versions close on loss of air, which is the required safe state for most gas cabinet and tool hook-up isolation points.

How do I order the VX12-LP?

Quote model VX12-LP together with the gas list, operating pressure, required Cv, port size, end connection and actuation. Material certificates, per-valve helium leak records and a certificate of conformance can be supplied with the order.

Browse valvesRequest a Quote