Valonix Fluid Systems — Specialty Gas Valves, Engineered for Puritysales@yuedukeji.cn  |  Get a quote
cylinder valves for specialty gas

Cylinder & High Pressure Valves

The cylinder connection is the first and most critical valve in any specialty gas system. Valonix cylinder and high pressure valves cover CGA and DISS outlet standards, 20 MPa tube trailer duty and pneumatically actuated isolation for high pressure cylinder cabinets.

These valves are built for the front and rear compartments of tube trailers, high pressure pipeline systems and special gas cylinders where a leak is both a safety and a supply issue.

CGA and DISS outlet standards

Outlet connections must match the gas and the receiving equipment. CGA 632 through CGA 728 and DISS 6/7 series cover different media, and using an adapter instead of the correct outlet is a common compliance failure. State the gas and the required connection when ordering.

  • CGA 632-728 variants by media
  • DISS 6/7 series connections
  • Match outlet to gas, never adapt a mismatched one

20 MPa high pressure pneumatic valves

Pneumatically actuated 20 MPa valves in 3/8, 1/2 and 3/4 in butt-weld sizes allow remote isolation of tube trailer compartments and high pressure headers. A 3/4 NGT cylinder-thread variant is available for direct cylinder mounting.

  • 20 MPa working pressure
  • 3/8, 1/2 and 3/4 in butt weld
  • 3/4 NGT cylinder thread option

Safety and verification

High pressure cylinder valves should be helium leak tested, proof tested and supplied with material traceability. Confirm the safe state of pneumatic versions and include the valve in the cabinet interlock and emergency shutdown logic.

  • Helium leak and proof testing
  • Material traceability on request
  • Include in cabinet ESD interlock logic

Valves in this category

Typical specifications

Working pressure20 MPa (approx. 2900 PSI)
Port sizes3/8", 1/2", 3/4"
ConnectionsButt weld, 3/4 NGT, CGA, DISS
ActuationManual or pneumatic
ServiceTube trailer, cylinder cabinet, HP header
TestingHelium leak and hydrostatic proof

Frequently Asked Questions

Which CGA connection do I need?

It depends on the gas. Provide the gas name and the receiving equipment standard; we will match the correct CGA or DISS outlet rather than supply an adapter.

Are 20 MPa valves suitable for tube trailers?

Yes, the CV20 family is designed for front and rear compartments of tube trailers and high pressure pipeline systems.

Do you supply material certificates?

Material traceability and test records can be supplied on request; state the requirement when quoting.

Specifying a new line? Include the gas list, maximum pressure, required Cv, port size and whether the valve must fail closed. Request a quote.
Browse valvesRequest a Quote